Volume 89, № 5
COMPUTER SIMULATION OF THE ELASTIC PROPERTIES OF TITANIUM ALLOYS FOR MEDICAL APPLICATIONS
Results of a computer simulation of the elastic properties of α+β- and β-titanium alloys, used for medical purposes, within the framework of the molecular-dynamics method are presented. It is shown that β-titanium alloys are best
suited for the use as bone implants because of their small moduli of elasticity. The advisability of the use of the molecular-dynamics method for the study of the elastic properties of titanium alloys, serving as bone implants, is
demonstrated.
Results of a computer simulation of the elastic properties of α+β- and β-titanium alloys, used for medical purposes, within the framework of the molecular-dynamics method are presented. It is shown that β-titanium alloys are best
suited for the use as bone implants because of their small moduli of elasticity. The advisability of the use of the molecular-dynamics method for the study of the elastic properties of titanium alloys, serving as bone implants, is
demonstrated.
Author: Elsa Paz Estevez, R. M. Burganova and Yu. V. Lysogorskii
Keywords: titanium alloys of medical application, modulus of elasticity, molecular dynamics, MedeA-LAMMPS
Page: 1344
			
Elsa Paz Estevez, R. M. Burganova  and Yu. V. Lysogorskii. 
COMPUTER SIMULATION OF THE ELASTIC PROPERTIES OF TITANIUM ALLOYS FOR MEDICAL APPLICATIONS //Journal of engineering physics and thermophysics. 
№5. Volume 89, № 5. P. 1344. 
		Back to list